Solar 6
Expanded photo at bottom
- ON-Time for each zone in the Solar 3B, Solar 6, and Solar 12C can be programmed in 1 second increments from 1 to 127 second of mist.
- REPEAT Interval for each zone in all three controllers can be programmed in either Minutes, or in Solar Units. When a zone is programmed for the Solar Mode, then the zone can be set to repeat every 1 to 127 Solar Units. One Solar Unit is accumulated by the Solar Misters when a light intensity of 2000 foot-candles shines for 1 minute, which equals 186 watts per square meter shining for 1 minute, and Also equals a solar accumulation of .02 Moles per square meter. When a zone is programmed for the Minutes Mode, the zone can be set in 1 minute increments to repeat from 1 to 127 minutes.
- The Solar 3B, Solar 6, and the Solar 12C can be programmed to mist during the night to compensate for dry air, or the drying affect of bottom heat. Nighttime Repeat intervals from 15 minutes to nearly 16 hours can be programmed (15 minute increments.).